Protocol
One-Step Fingerprint DNA Purification Protocol
Products
Components
Cat. No. AZ-101 (50 Preps)
2.5 ml
Cat. No. AZ-102 (100 Preps)
5.0 ml
Cat. No. AZ-101 (50 Preps)
0.6 ml
Cat. No. AZ-102 (100 Preps)
1.2 ml
Cat. No. AZ-101 (50 Preps)
12.5 mg
Cat. No. AZ-102 (100 Preps)
25 mg
Cat. No. AZ-101 (50 Preps)
15.4 mg
Cat. No. AZ-102 (100 Preps)
30.8 mg
Cat. No. AZ-101 (50 Preps)
1.0 ml
Cat. No. AZ-102 (100 Preps)
2.0 ml
Shipping conditions: At ambient temperature
Components
BcMag™ U-DNA Beads
10x Lysis Buffer (100mM Tris-HCl, PH 9.0)
Proteinase K
DTT
Proteinase K Suspension Buffer
Storage
4°C
4°C
-20°C
-20°C
4°C
Cat. No. AZ101 (50 Preps)
2.5 ml
0.6 ml
12.5 mg
15.4 mg
1.0 ml
Cat. No. AZ102 (100 Preps)
5.0 ml
1.2 ml
25 mg
30.8 mg
2.0 ml
Shipping conditions: At ambient temperature
Handling and Storage: Store the kit components according to the table Above on arrival.
Introduction
BcMag™ One-Step Fingerprint DNA Purification Kit allows rapid and efficient extraction of genomic DNA from fingerprint or other samples containing touch DNA. It uses novel negative selection chromatography magnetic beads to quickly capture and remove impurities, such as PCR inhibitors, from the cell lysate, leaving the DNA intact. Compared to the traditional DNA extraction process that involves multiple steps of binding, washing, and elution, the extraction kit provides a fast and straightforward DNA extraction method with only one tube and does not require carrier RNA. After preparing the lysates, hundreds of samples can be processed in under 30 minutes without requiring expensive equipment.
Principle and purification results
The specially designed magnetic beads with our proprietary surface chemistry function capture the impurity once mixed with the sample. The magnetic beads-impurity complex is then magnetically removed by a magnet while the pure DNA remains in the solution.
Workflow of Fingerprint DNA isolation
1.
Add functional magnetic beads to the sample.
2.
Mix the samples with the magnetic beads and proteinase K to lyse the cells.
3.
Mix by vortexing/pipetting for the beads to capture the PCR inhibitors.
4.
Remove the beads with a magnet.
5.
Aspirate the supernatant containing the pure ready-to-use DNA/RNA
Performance
The purified DNA is suitable for use in sensitive downstream applications, such as PCR, qPCR, single-nucleotide polymorphism (SNP), short tandem repeat (STR) genotyping, genotyping, or next-generation sequencing (NGS), buccal DNA sample collection, veterinary genotyping and diagnostics, research genotyping, Veterinary genotyping and diagnostics, genetic testing, forensics, population studies.
Features and Advantages
●
Rapid and efficient extraction protocol: without prior DNA isolation for subsequent use in direct workflows, No liquid transfer, and One-tube.
●
Ultrafast: Process 96 samples in less than an hour.
●
Highest nucleic acids recovery rates: Minimal loss of DNA during extraction
●
●
Cost-effective: Eliminates columns, filters, laborious repeat pipetting, and organic reagents.
●
High throughput: Compatible with many different automated liquid handling systems.
PROTOCOL
The following protocol is an example. The protocol can be scaled up or down as needed.
Notes
●
DNA Yield: Varies (depends on sample size and type)
●
DNA Size: Varies (depends on the quality of starting material)
●
Since there is no concentration step in the protocol, the concentration of the nucleic acid depends on the quality and quantity of the sample used.
●
Quantification of the nucleic acids: Use only fluorescence methods such as qPCR, Qubit, and Pico Green.
●
OD260 methods such as Nanodrop and UV-spectrophotometry are not-suitable.
●
For long-term storage, store the extracted nucleic acids at -20°C.
A. Materials Required by the User
Item
Magnetic Rack for centrifuge tube
** Based on sample volume, the user can choose one of the following magnetic Racks
Source
• BcMag™ Rack-2 for holding two individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-01)
• BcMag™ Rack-6 for holding six individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-02)
• BcMag™ Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Bioclone, Cat. No. MS-03)
• BcMag™ Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-04)
Item
BcMag™ 96-well Plate Magnetic Rack.
Source
• BcMa™ 96-well Plate Magnetic Rack (side-pull) compatible with 96-well PCR plate and 96-well microplate or other compatible Racks (Bioclone, Cat. No. MS-06)
Item
Adjustable Single and Multichannel pipettes
Item
Centrifuge with swinging bucket
Addition items are required if using 96-well PCR plates / tubes
Vortex Mixer
** The user can also use other compatible vortex mixers. However, the Time and speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 2000 rpm
Eppendorf™ MixMate™
Eppendorf, Cat. No. 5353000529
Tube Holder PCR 96
Eppendorf, Cat. No. 022674005
Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL
Eppendorf, Cat. No. 022674048
Smart Mixer, Multi Shaker
BenchTop Lab Systems, Cat. No. 5353000529
1.5/2.0 mL centrifuge tube
96-well PCR Plates or 8-Strip PCR Tubes
! IMPORTANT ! If using other tubes or PCR plates, make sure that the well diameter at the bottom of the conical section of PCR Tubes or PCR plates must be ≥2.5mm.
Items
Magnetic Rack for centrifuge tube
** Based on sample volume, the user can choose one of the following magnetic Racks
Source
●
BcMag™ Rack-2 for holding two individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-01)
●
BcMag™ Rack-6 for holding six individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-02)
●
BcMag™ Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Bioclone, Cat. No. MS-03)
●
BcMag™ Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-04)
BcMag™ 96-well Plate Magnetic Rack
●
BcMa™ 96-well Plate Magnetic Rack (side-pull) compatible with 96-well PCR plate and 96-well microplate or other compatible Racks (Bioclone, Cat. No. MS-06)
Adjustable Single and Multichannel pipettes
Centrifuge with swinging bucket
Addition items are required if using 96-well PCR plates/tubes
Vortex Mixer
** The user can also use other compatible vortex mixers. However, the Time and Speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 2000 rpm
Eppendorf™ MixMate™
Tube Holder PCR 96
Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL
Smart Mixer, Multi Shaker
Eppendorf, Cat. No. 5353000529
Eppendorf, Cat. No. 022674005
Eppendorf, Cat. No. 022674048
BenchTop Lab Systems, Cat. No. 5353000529
Eppendorf™ MixMate™
Tube Holder PCR 96
Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL
Eppendorf, Cat. No. 5353000529
Eppendorf, Cat. No. 022674005
BenchTop Lab Systems, Cat. No. 5353000529
1.5/2.0 mL centrifuge tube
96-well PCR Plates or 8-Strip PCR Tubes
PCR Plates/Tubes
! IMPORTANT ! If using other tubes or PCR plates, make sure that the well diameter at the bottom of the conical section of PCR Tubes or PCR plates must be ≥2.5mm.
Sample Preparation
In criminal cases, sampling techniques are critical for gathering the best evidence. Swabbing, rather than taping, is the preferred sample collection method for recovering DNA. Swabs are also preferable to cuttings because they better collect and release samples than tape. However, getting the most accurate results depends on using suitable swabs for the job.
Type of swabs
Cotton swabs are the most commonly used for collecting specimens at crime scenes. We recommend DNA, DNase, and RNase-free Double Precision tips.
Swabbing for Fingerprint DNA
●
If using a dry swab, use a sterile pipette to extract distilled water from the vial and apply 30µl to the side of the tip. Use no more than 30µl and do not immerse the swab in water.
●
Apply the fine tip to the sample area and rotate the swab with moderate pressure. Only rotate the specimen once to avoid compromising the sample by redepositing it.
●
Use a dry swab to collect the remainder of the specimen from the same spot.
●
Cut the swab tip with scissors and place it in a clean PCR tube.
B. Premix Beads Solution Preparation
! IMPORTANT !
1.
Before pipetting, shake or Vortex the bottle to completely resuspend the Magnetic Beads.
2.
Do not allow the magnetic beads to sit for more than 2 minutes before dispensing.
3.
Proteinase K preparation: Provide protease K as lyophilized powder and dissolve at a 20 mg/ml concentration in Proteinase K Suspension Buffer. For example, 12.5 mg dissolved in 625 µl of Proteinase K Suspension Buffer. Divide the stock solution into small aliquots and store at -20°C. Each aliquot can be thawed and refrozen several times but should then be discarded.
4.
DTT solution preparation: Provide DTT as powder and dissolve at a concentration of 1M in ultrapure water. For example, 15.4 mg dissolved in 100µl ultrapure water. It is stable for years at -20°C. Prepare in small aliquots, thaw it on ice, and use and discard. Store them in the dark (wrapped in aluminum foil) at -20°C. Do not autoclave DTT or solutions containing it. Avoid multiple freeze-thaw cycles.
5.
Dilute DTT to a concentration of 10 mM from stock with ultrapure water and use it immediately. Discard unused DTT solution.
6.
Prepare a fresh Master Mix following Table 2 for the number of samples to be processed, plus 10% more (e.g, if you have 10 samples, prepare a Master Mix for 11). Add the following components to the reservoir.
Table 2. Premix Beads solution
Components
BcMag™ U-DNA Beads
10x Lysis Buffer
Proteinase K (20mg/ml)
DTT (10 mM)
Sample
Ultrapure Water
Total
One Well ( 100 μL Reaction Volume)
50 μL
10 μL
12.5 μL
3 μL
x
x
100 μL
Components
50 μL
10 μL
12.5 μL
3 μL
x
x
100 μL
C. Isolation Procedure
! IMPORTANT !
●
Pipet up and down premix beads solution in a reagent reservoir until the solution is homogeneous before dispensing.
●
Do not allow the magnetic beads to sit for more than 5 minutes before dispensing.
1.
Transfer 25-30µl premix beads solution (Table 2) to the sample tube.
2.
Mix the sample well by pipetting or vortex.
3.
Place the PCR plate/tube into a thermocycler and incubate at:
a.
65°C for 15 minutes
b.
80°C for 10 minutes
4.
Remove the PCR plate/tube from the thermocycler and then mix the sample with beads by slowly pipetting up and down 20-25 times, or Vortex the sample at 2000 rpm for 5 minutes (see picture).
5.
Centrifuge at 3500 rpm for 5 minutes.
6.
Place the sample plate/tube on the magnetic separation plate for 30 seconds or until the solution is clear.
7.
Transfer the supernatant to a clean plate/tube while the sample plate remains on the magnetic separation plate. The sample is ready for downstream applications. Using 1-5 μl in a 25μl RT-PCR or qPCR.
D. Troubleshooting
Problem
Low DNA/RNA Recovery
Probable Cause
Poor starting sample material
Suggestion
- Use better-quality samples.
- Add more samples
Problem
Ct Value Delays
Probable Cause
Too many PCR inhibitors in the sample.
Suggestion
- Add 25-50 μL BcMag™ U-DNA Beads to the extract solution and mix by slowly pipetting up and down 20-25 times or Vortex the sample at 2000 rpm for 5 minutes. Place the sample plate/tube on the magnetic separation plate for 30 seconds or until the solution is clear.
- Transfer the supernatant to a clean plate/tube while the sample plate remains on the magnetic separation plate. Using 1-5 μl in a 25μl RT-PCR or qPCR. The sample is ready for downstream applications.
Problem
Ct Value Delays
Probable Cause
Recovery DNA is so low.
Suggestion
- Use better-quality samples.
- Add more samples
Problem
Probable Cause
Suggestion
Low DNA/RNA Recovery
Poor starting sample material
- Use better-quality samples.
- Add more samples
Ct Value Delays
Too many PCR inhibitors in the sample.
- Add 25-50 μL BcMag™ U-DNA Beads to the extract solution and mix by slowly pipetting up and down 20-25 times or Vortex the sample at 2000 rpm for 5 minutes. Place the sample plate/tube on the magnetic separation plate for 30 seconds or until the solution is clear.
- Transfer the supernatant to a clean plate/tube while the sample plate remains on the magnetic separation plate. Using 1-5 μl in a 25μl RT-PCR or qPCR. The sample is ready for downstream applications.
Recovery DNA is so low.
- Use better-quality samples.
- Add more samples