Products

Super Bright Protein L Europium Fluorescent Magnetic Beads: Overcoming Limitations of Conventional Fluorophores

Products

2.5 μm BcMag™ Protein L Europium Fluorescence Magnetic Beads
Cat. No.  HP101

Unit Size  0.5 ml
Order
2.5 μm BcMag™ Protein L Europium Fluorescence Magnetic Beads
Cat. No.  HP102

Unit Size  1.5 ml
Order
5 μm BcMag™ Protein L Europium Fluorescence Magnetic Beads
Cat. No.  HP103

Unit Size  0.5 ml
Order
5 μm BcMag™ Protein L Europium Fluorescence Magnetic Beads
Cat. No.  HP104

Unit Size  1.5 ml
Order
Previous slide
Next slide

Cat. No.

Product Name

Unit Size

Order

HP101

2.5 μm BcMag™ Protein L Europium Fluorescence Magnetic Beads

0.5 ml

HP102

2.5 μm BcMag™ Protein L Europium Fluorescence Magnetic Beads

1.5 ml

HP103

5 μm BcMag™ Protein L Europium Fluorescence Magnetic Beads

0.5 ml

HP104

5 μm BcMag™ Protein L Europium Fluorescence Magnetic Beads

1.5 ml

Fluorescence Dye Properties

Fluorophore

Fluorescence
Color

Excitation
(nm)

Emission
(nm)

Fluorescence lifetime
(Ԏ) (µsec)

Stokes shifts
(nm)

Selection of
Emission Filter

Europium ion (Eu3+)

Red

340

615

730

275

620/40

Fluorescence Dye Properties

Fluorophore

Europium ion (Eu3+)
Fluorescence
color

Red

Excitation
(nm)

340

Emission
(nm)

615

Fluorescence lifetime (Ԏ) (µsec)

730

Stokes shifts
(nm)

275

Selection of
Emission Filter

620/40

Specification

Bead Size

2.5μm diameter; 5μm diameter

Number of Beads

~ 10 x 107 beads/mg (2.5μm)

~ 5 x 107 beads /mg (5μm)

Magnetization

~40-45 EMU/g

Type of Magnetization

Superparamagnetic

Concentration

10 mg/ml (10mM Tris, 0.15 M NaCl, 0.1% BSA,1 mM EDTA, pH7.4)

Binding Capacity

~ 350 μg IgG/ml of Beads

Storage

Ship at room temperature. Store at 4°C. Do not freeze.

Description

BcMag™ Protein L Europium Fluorescence Magnetic Beads are Time-Resolved Fluorescence (TRF) magnetic microspheres that are covalently coupled with Protein L on the surface. The microspheres combine the benefits of a novel antibody-binding protein, time-resolved Fluorescence dyes, and magnetic characteristics to perform very sensitive assays. The beads are manufactured using nanometer-scale superparamagnetic iron oxide and europium metal as core and entirely encapsulated by a high-purity silica shell, ensuring no leaching problems with the iron oxide and europium metal.

Europium Fluorescence Magnetic Beads

Despite being widely utilized over the past few decades, conventional fluorophores still face several limitations that hinder their effectiveness and applicability. These limitations include a narrow excitation band that can lead to higher background signals, a smaller Stokes shift that may result in self-quenching, sensitivity to environmental factors such as pH, temperature, metallic ion concentration, and solvent polarity, low fluorescence intensity that may not be sufficient for detecting a single biomolecule, fluorescence intermittency (blinking) that can affect molecule detection processes, and a tendency to aggregate due to hydrophobicity.

BcMag™ TR-FRET (Time-Resolved FRET) Assay

BcMag™ TR-FRET Assay, in contrast to typical FRET (Förster Resonance Energy Transfer) assays, uses time-resolved Fluorescence magnetic beads (BcMag™ TR-Magnetic Beads) as the donor fluorophore. The donor and acceptor can be two proteins, two DNA strands, an antigen, an antibody, or a ligand and its receptor. After a reasonable time delay (usually 50 to 100 s), a signal is generated by fluorescence resonance energy transfer between a donor and an acceptor molecule when they are close and monitored in a time-resolved way. In BcMag™ TR-FRET Assay, a trace amount of analytes can be easily enriched from the complex by TR-Magnetic Beads, resulting in higher sensitivity. This assay practically eliminates all fluorescence backgrounds caused by the sample and plastic microplate, as well as by direct acceptor excitation. As a result, the signal-to-noise ratios of the BcMag™ TR-FRET Assay are very high, and the background is quite low. Furthermore, the assay does not need washing steps. BcMag™ TR-FRET Assay offers substantial advantages to bioassays in high throughput screening, such as assay flexibility, dependability, increased assay sensitivity, higher throughput, and fewer false positive/false negative results.

Europium cryptate fluorophore is an efficient time-resolved Fluorescence tag due to its distinct specific properties. It is excited at 340nm and emits red fluorescence at 615nm, with a long fluorescence lifetime (730 μsec) and large stokes shifts (275 nm). By taking advantage of these properties, time-resolved fluorescence measurement can dramatically reduce the fluorescence background from the sample and increase the signal-to-noise ratio to offer detectability better than one order of magnitude than conventional Fluorescence dyes. BcMag™ Protein L Europium Fluorescence Magnetic Beads are excellent donors used in TR-FRET assays.

Workflow of TR-FRET Magnetic Beads Assay

1.

Mix the antibody-conjugated donor beads with the cell lysates and incubate them with continuous rotation for a sufficient time. The beads remain suspended in the sample solution during mixing, allowing the target analytes to bind to the donor beads.

2.

After incubation, the beads are collected and separated from the sample using a magnet rack.

3.

Add the antibody-conjugated acceptor and incubate them with continuous rotation for a sufficient time.

4.

Analysis of numerous microplate readers supports TR-FRET measurements.

Workflow of TR-FRET Magnetic Beads Assay

Advantages and Benefits

1.

Perform a double function simultaneously on the same beads: The magnetic beads combine separation/preconcentration and detect analytes, allowing quick, simple, robust, and high-throughput analytes of trace amounts from complex biological samples on the same beads.

2.

Ultra sensitive. Lower detection limits of 10 pg/mL versus typical fluorometric detection limits of 100 pg/mL.

3.

Extremely photostable and highly resistant to photobleaching. All the lanthanide chelate or cryptate molecules and iron oxide are entirely encapsulated inside each bead instead of merely on the bead’s surface. The protective environment prevents iron oxide and dye from leaching into aqueous media, which makes the beads less sensitive to external conditions such as solvent, temperature, pH, etc.

4.

Very high Fluorescence intensity. Because a single bead has a large concentration of lanthanide chelate with a high quantum yield ranging from 40 to 90%, the beads show excellent fluorescence intensity, which increases test sensitivity without signal amplification. Such bright beads are also perfect for donors’ use in time-resolved FRET assays.

5.

Lanthanide chelate or cryptate has large Stokes shifts (>250 nm), narrow emission bands (-10 nm bandwidth), and long fluorescence lifetime (μs), which dramatically reduces background and increases the signal-to-noise ratio.

6.

Most bioprocess ELISA assays can be converted to an HTRF assay.

7.

No washing step is involved in the assays.

8.

Have a hydrophilic silica surface grafted by different functional groups with linkers of variable lengths, allowing efficient conjugation of various ligands such as peptides, proteins, antibodies, small molecules, carbohydrates, aptamers, DNA/RNA, etc.

9.

Due to the microsphere’s magnetic properties, the Fluorescence magnetic beads are suitable for high-throughput automation.