Guest

Bioclone

Products

Protein A/G Magnetic Beads

Products

BcMag™ Protein A/G Magnetic Beads Purification Kit
Kit Components:
2.0 ml BcMag™ Protein A/G magnetic beads
25 ml 5x Binding/Washing Buffer
2.0 ml 1x Elution Buffer
2.0 ml 1x Neutralization


Cat. No.  MA101

Unit Size  Each
Order
BcMag™ Protein A/G Magnetic Beads
Cat. No.  MA102

Unit Size  5 ml
Order
BcMag™ Protein A/G Magnetic Beads
Cat. No.  MA103

Unit Size  10 ml
Order
Previous slide
Next slide

Cat. No.

Product Name

Unit Size

Order

MA101

BcMag™ Protein A/G Magnetic Beads Purification Kit

Kit components:

– 2.0 ml BcMag™ Protein A/G magnetic beads

– 25 ml 5x Binding/Washing Buffer

– 2.0 ml 1x Elution Buffer

– 2.0 ml 1x Neutralization

Each

MA102

BcMag™ Protein A/G Magnetic Beads

5 ml

MA103

BcMag™ Protein A/G Magnetic Beads

10 ml

Specification

Beads Size

~ 2.5 μm diameter

Number of Beads

~ 1.7 x 107 beads

Magnetization

~ 40 EMU/g

Type of Magnetization

Superparamagnetic

Effective Density

2.5 g/ml

Stability

Short term: pH 3-11; Long term: pH 4-10

Binding Capacity

~ 1 mg IgG/ml of Beads

Storage

Store at 4ºC upon receipt

Shipping conditions: At ambient temperature

Handling and Storage: Store the kit components according to the table above on arrival.

Description

Introduction

The BcMag™ Magnetic Beads offer a rapid, effective, and expedient chromatography technique to isolate biomolecules such as DNA, RNA, proteins, lipids, and carbohydrates from intricate biological samples using both manual and automated workflows.

The BcMag™ Protein A/G Magnetic Beads are affinity particles with high capacity and throughput, designed for antibody purification and immunoprecipitation processes that can be carried out manually or by robotic magnetic racks. These magnetic microspheres are covalently linked with a high-density ultrapure (Purity>97%) recombinant protein A/G protein. The utilization of Protein A/G Magnetic Beads enables the extraction of antibodies from serum, cell culture supernatant, or ascites, as well as the isolation of antigen IP/Co-IP from cell or tissue extracts. The method for using Protein A/G Magnetic Beads has been improved to enable the maximum recovery and purity of the extracted antibody or antigen. In the case of antibody purification, the beads are allowed to incubate with the antibody solution, after which they are magnetically separated from the supernatant. For immunoprecipitation, the beads are introduced into an antigen-containing sample where an antibody is present, and left to incubate, forming the antibody-antigen complex. The bound antibodies or antigens are then dissociated from the beads using an elution buffer and manually recovered from the solution using a magnetic stand or automated instruments.

Protein A/G is a genetically engineered recombinant fusion protein that includes four Fc binding domains from Protein A and two from Protein G and has a final mass of 50.4 kDa. Protein A and Protein G are antibody-binding proteins derived from Staphylococcus aureus and Streptococcus sp., respectively. These proteins have different immunoglobulin-binding capacities and specificity. Protein A/G is a more potent protein exhibiting less pH-dependent binding and has binding profiles of both the proteins compared to Protein A or Protein G alone. Protein A/G strongly binds to human total IgG, IgG1, IgG2, IgG3, and IgG4, which is ideal for binding polyclonal or monoclonal IgG antibodies, whose subclasses are unsure yet. In the case of mouse IgG, Protein A/G can bind to all classes, including total IgG, IgG1, IgG2a, IgG2b, and IgG3 – except IgA, IgM, and serum albumin, allowing Protein A/G to efficiently purify and detect mouse monoclonal IgG antibodies, without cross-binding to IgA, IgM and serum albumin. Also, Protein A/G binds more powerfully and efficiently to mouse monoclonal antibodies than to Protein A or Protein G alone. The antibody binding properties are summarized in Table 1.

Table 1. Protein A/G binding properties

Species

Antibody

Binding
(Protein A/G)

Mouse

IgG 1

IgG 3

IgG 2a

IgG 2b

IgM

Total IgG

+++

++++

++++

++++

++++

Human

IgG1

IgG2

IgG3

IgG4

IgA

IgD

IgM

Fab

scFv

Total IgG

++++

++++

++++

++++

++

++

++

++

++++

Rat

IgG 1

IgG 2a

IgG 2b

IgG 2c

Total IgG

+++

++++

++

++++

+++

Species

Antibody

Binding
(Protein A/G)

Sheep

IgG1

IgG2

Total IgG

++++

++++

++++

Horse

IgG(ab)

IgG(c)

IgG(T)

Total IgG

++

++

++++

++++

Goat

IgG1

IgG2

Total IgG

++++

++++

++++

Cow

IgG1

IgG2

Total IgG

++++

++++

++++

Rabbit

Total IgG

++++

Guinea Pig

Total IgG

++++

Pig

Total IgG

++++

Cat

Total IgG

++++

Dog

Total IgG

++++

++++ (Strong Binding)

+++ (Medium Binding)

++ (Weak Binding)

– (No Binding)

N/A (No Information)

 

BcMag™ Protein A/G Magnetic Beads are magnetic microspheres covalently immobilized with a high density ultrapure (Purity>97%) recombinant protein A/G fusion proteins. The beads are manufactured using nanometer-scale superparamagnetic iron oxide as core and entirely encapsulated by a high purity silica shell, ensuring no leaching problems with the iron oxide. Beads are specifically designed, tested, and quality controlled for immunoprecipitation and cell sorting when a selected primary antibody is used. Additionally, the beads are widely used for quick and efficient one-step purification of antibodies from Serum samples, ascites fluid, plasma, or tissue culture supernatant from several species.

Although agarose columns or beads are commonly used as solid support matrices in chromatographic techniques, their procedures for sample preparation are tedious, time-consuming, unable to handle large numbers of samples in a short time, and challenging to adapt to the automation system. Selecting a new affinity matrix is necessary to reduce elution volumes, enabling increased process intensification and throughput. Magnetic beads (particles) are an entirely different type of solid support matrices from beaded agarose or other porous resins. They are much smaller (typically 1-5 μm diameter), thus providing larger surface areas for a high density of ligand immobilization. In addition, the microspheres combine all the advantages of affinity protein purification (low costs, simplicity, high specificity, and capacity) and magnetic properties to perform efficient manual or automatic quick high-throughput applications.

Features and Advantages

Quick, Easy, and one-step high-throughput procedure; eliminates columns or filters or a laborious repeat of pipetting or centrifugation.

High efficiency – produces the same or more IP target antigens as magnetic beads from other providers.

Low nonspecific binding – highly pure product is provided by stable, pre-blocked beads

Consistent – magnetic beads reduce resin loss and allow more efficient separation than classic IP methods that rely solely on centrifugation.

Beads are versatile since they can be used in both human and automated procedures.

Applications

Immunoprecipitation including IP, Co-IP, ChiP, RIP

Cell sorting

High-throughput screening and purification of antibodies

Protocol for antibody purification

Using Protein A/G Magnetic beads to purify the antibody from the serum as an example, the general purification protocol is as follows:

Antibody purification protocol using Protein A/G

1.

Materials Required

a.

Buffer Composition

BcMag™ Protein A/G Beads (10 mM Tris, 0.15 M NaCl, 0.1% BSA,1 mM EDTA, pH7.4, 0.1% NaN3)

1x Protein A/G Binding/Washing Buffer (57.7 mM Na2HPO4,42.3 mM NaH2PO4, pH 7.0)

1x Protein A/G Elution Buffer (0.2 M Glycine/HCl, pH 2.5)

1x Protein A/G Neutralization Buffer (1.0 M Tris-HCl, pH 9.0)

b.

Equipment

Magnetic Rack (for manual operation)

Based on sample volume, the user can choose one of the following Magnetic Racks:

– BcMag™ Magnetic Rack-2 for holding two individual 1.5 ml centrifuge tubes (Cat. No. MS-01);

– BcMag™ Magnetic Rack-6 for holding six individual 1.5 ml centrifuge tubes (Cat. No. MS-02);

– BcMag™ Magnetic Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Cat. No. MS-03);

– BcMag™ Magnetic Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Cat. No. MS-04);

– BcMag™ Magnetic Rack-96 for holding a 96 ELISA plate or PCR plate (Cat. No. MS-05).

For larger scale purification, Ceramic magnets Block for large scale purification ( 6 in x 4 in x 1 in block ferrite magnet, Applied Magnets, Cat. No. CERAMIC-B8)

Corning 430825 cell culture flask for large-scale purification (Cole-Parmer, Cat. No. EW-01936-22)

Mini BlotBoy 3D Rocker, fixed speed, small 10″ x 7.5″ platform w/ flat mat (Benchmark Scientific, Inc. Cat. No. B3D1008) or compatible

2.

Procedure

Note:

1.

This protocol is optimized for purifying most IgG antibodies from different sources. However, designing a universal kit for all IgG purification is impossible because no two antibodies are precisely alike. To obtain the best results, each user should determine the optimal working conditions for the purification of individual antibodies, especially for those weakly-binding antibodies (see Table 1).

2.

It is necessary to dilute serum samples, ascites fluid, or tissue culture at least 1:1 with Binding/Washing buffer before the purification.

3.

Before purifying IgG, the user should equilibrate all the reagents in the kit to room temperature and make 1x working solutions by diluting stock solutions with dH2O.

A.

Magnetic Beads Preparation

1.

Vigorously shake the bottle until the magnetic beads become homogeneous and transfer an appropriate volume of the magnetic beads to a new tube or flask.

Note:

Optimize the number of beads used for each application. Too many beads will cause higher background. Insufficient beads will lead to lower yields. We recommend 100 μl of the wholly suspended beads per 200 μg of IgG antibodies. Typically, a high-titer antiserum has roughly 5 mg/ml of IgG for rabbits, 10 mg/ml of IgG for Mouse ascites, and 20 mg/ml of IgG for goat or sheep antiserum.

Do not allow the beads to sit for more than 5 minutes before dispensing. Resuspend the magnetic beads every 3 minutes.

2.

Place the tube on the magnetic rack for 1-3 minutes. Remove the supernatant while the tube remains on the rack. Add ten bead-bed volumes of 1x Binding/Washing Buffer and mix the beads by pipetting or vortex. Place the tube on the magnetic rack for 1-3 minutes and remove the supernatant while the tube remains on the rack.

3.

Repeat step (2) one more time. The beads are ready for purification.

B.

Purification

1.

Add an equal volume of 1x Binding/Washing Buffer to the sample and mix well.

2.

Mix the equilibrated beads [Step A (3)] to the sample and incubate on Mini BlotBoy 3D Rocker with continuous rotation for 5-10 minutes at room temperature or 30-45 minutes at 4ºC.

3.

Place the tube on the magnetic rack for 1-3 minutes. Remove the supernatant while the tube remains on the rack. Add 10 bead-bed volumes of 1x Binding/Washing Buffer and shake it 10 times to wash the beads. Place the tube on the magnetic rack for 1-3 minutes and remove the supernatant while the tube remains on the rack.

4.

Repeat step (3) six times.

Note:

This step is critical to get high pure protein. It may be necessary to wash the beads more than six times for some proteins to reduce the nonspecific binding.

Add a nonionic detergent (0.5% Triton X 100, 0.5% Tween 20) to the binding/washing buffer, which may reduce the nonspecific binding.

5.

Add an appropriate amount of Elution Buffer and mix well by pipetting up and down 10-12 times or vortex mixer for 5 minutes.

6.

Collect and transfer the antibody-containing supernatant to a new tube. Immediately neutralize the eluted antibody solution by adding 1/10th volume of neutralization buffer and mix well.

Questions and Answers

1.

Sometimes, why could IgG not be eluted from the magnetic beads?

The pH of the Elution Buffer may be incorrect. The correct pH should be 2.5.

The elution conditions are too mild to elute the antibody.

Because a few antibodies can only be eluted at pH 2.0.

2.

What accounts for lost or decreased immuno-reactivity of the eluted antibody?

It will not influence the immuno-reactivity of most antibodies once a Neutralization Buffer is added, immediately neutralizing the eluted fraction. However, a few antibodies (e.g., some monoclonal antibodies) are acid-labile and can irreversibly lose their activity at very low pH values. For those low pH sensitive antibodies, One-Step Antibody Purification Kit is an alternative method for antibody purification. The kit is a rapid, one-step, and effective method of isolating the antibodies from serum and other sample types. The magnetic beads bind and remove serum proteins, allowing pure IgG to be collected in the supernatants. The antibody keeps 100% activity since no harsh elution conditions are involved.
Antibody purification by BcMag™ One-minute antibody purification Kit

3.

Why are multiple bands observed in the eluted antibody solution?

Some host proteins may nonspecifically interact with your target antibody. Users can add NaCl (50-200mM, final concentration) to the binding and elution buffers.

Protocol for Immunoprecipitation

A.

Additional Materials Required

1.5mL microcentrifuge tubes

Antibody for immunoprecipitation

Antigen sample

Lysis Buffer: 20 mM Tris HCl pH 8,137 mM NaCl,1% Nonidet P-40 (NP-40),2 mM EDTA. Store up to 6 months at 4°C. Immediately before use add protease inhibitor.

Wash buffers: 10mM Tris, pH 7.4, 1mM EDTA,1mM EGTA; pH 8.0, 0.5 M NaCl,1% Triton X-100, 0.05% Tween-20 0.2mM sodium orthovanadate, Protease inhibitor cocktail. Store up to 6 months at 4°C. Immediately before use add protease inhibitor. 0.05% Tween-20 Detergent and 0.5M NaCl.

Elution Buffer (0.2 M Glycine/HCl,pH 2.5)

Neutralization Buffer (1.0 M Tris-HCl, pH 9.0)

B.

Magnetic rack

Based on sample volume, the user can choose one of the following Magnetic Racks:

– BcMag™ Magnetic Rack-2 for holding two individual 1.5 ml centrifuge tubes (Cat. No. MS-01);

– BcMag™ Magnetic Rack-6 for holding six individual 1.5 ml centrifuge tubes (Cat. No. MS-02);

– BcMag™ Magnetic Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Cat. No. MS-03);

– BcMag™ Magnetic Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Cat. No. MS-04);

– BcMag™ Magnetic Rack-96 for holding a 96 ELISA plate or PCR plate (Cat. No. MS-05).

C.

Immunoprecipitation procedure

Note: This protocol is an example of immunoprecipitation and will require optimization for each application.

1.

Sample preparation

a.

Adherent cells

a)

Place the cell culture dish or flask on ice, aspirate media, and wash the cells with cold PBS.

b)

Aspirate PBS, then add appropriate volume ice cold lysis buffer (1 mL per 107 cells/100 mm2 dish/150 cm2 flask; 0.5 ml per 5×106cells/60 mm2 dish or 75 cm2 flask)

Note: Optimizing the volume of lysis buffer is necessary to ensure complete lysis and an optimal final protein concentration in the lysate.

c)

Incubate for 20 minutes on ice and then Scrape adherent cells off the dish or flask using a cell scraper and transfer the cell suspension into a microfuge tube and clarify the lysate by spinning for 10 minutes at 13,000 rpm, at 4°C.

d)

Collect the supernatant (avoiding the pellet) into a new microfuge tube. Determine protein concentration by appropriate methods.

e)

Proceed with the immunoprecipitation or Store at -20°C or -80°C until needed.

b.

Suspension Cells

a)

Transfer cells into a conical tube.

b)

Spin to pellet cells at low speed at 1400 rpm for 5 minutes at room temperature and aspirate off media.

c)

Wash pellet with 10 ml ice-cold PBS.

d)

Spin cells on low speed (at 1400 rpm), and Decant the PBS wash.

e)

Repeat wash and aspiration.

f)

Add an appropriate volume of ice-cold lysis buffer (10 to 100 μl per 2 x 106 cells) and Incubate cells for 30 minutes on ice.

Note: If necessary, sonicate the lysates on ice for 20-30 seconds to shear genomic DNA and cellular components.

g)

Centrifuge at 13,000 rpm for 10 minutes at 4ºC.

h)

Collect the supernatant into a fresh tube and determine protein concentration by appropriate methods. Adjust concentration to 2.5 mg/ml with lysis buffer.

i)

Proceed with the immunoprecipitation or Store at -20°C or -80°C until needed.

c.

Lysates from tissue

a)

Chop the tissue into small pieces, and wash twice with ice-cold PBS.

b)

Transfer ~5 mg chopped tissue into a tube, and add 300µl cold lysis buffer. Homogenize with an electric homogenizer or sonicate on ice.

c)

Spin at 14000 rpm for 10 min at 4°C.

d)

Collect the supernatant into a fresh tube. Determine protein concentration by appropriate methods.

e)

Proceed with the immunoprecipitation or Store at -20°C or -80°C until needed.

2.

Combine the 100–150 μg cell lysate with an appropriate amount of antibody in a 1.5mL centrifuge tube and Bring the reaction volume to 400-500 μL with the Cell Lysis Buffer. Incubate the reaction for 1-2 hours at room temperature or overnight at 4ºC with continuous rotation.

Note: Optimizing the amount of antibodies used for each application is necessary. Excess antibodies will cause higher background. Insufficient antibodies will lead to lower yields. Performing a pilot experiment is required to determine the optimum amount of antibody titer for maximum binding to the protein of interest. Typically in such an experiment, increasing amounts of antibodies for a fixed amount of protein is performed to establish the optimum titer. The following is a general guideline for antibody use. For individual antibodies, check the antibody instruction sheet for recommended antibody concentration.

For 100–150 μg cell lysate, use:

1–5 μL polyclonal antiserum

1 μg affinity-purified polyclonal antibody

0.2–1 μL ascites fluid (monoclonal antibody)

20–100 μL culture supernatant (monoclonal antibody)

3.

Transfer the appropriate amount of BcMag™ Protein G Magnetic Beads into a 1.5mL microfuge.

Note:

Vigorously shake the bottle until the magnetic beads become homogeneous before use.

The amount of the beads for use can be determined by the beads’ antibody binding capacity (~ 60μg IgG/mg ) and the antibody used.

Do not allow the beads to sit for more than 5 minutes before dispensing. Resuspend the magnetic beads every 3 minutes.

4.

Wash the beads with 1ml of Wash Buffer and gently vortex to mix. Collect the beads by a magnet and remove and discard the supernatant.

5.

Add the antigen sample/antibody mixture to the pre-washed magnetic beads and incubate at room temperature for 1 hour with continuous rotation.

6.

Collect the beads by a magnet, remove the supernatant, and save them for analysis.

7.

Wash the beads with 500μL of Wash Buffer by pipetting up and down 10 times. Collect the beads and discard the supernatant.

8.

Repeat wash twice until the absorbance of the supernatants at 280 nm approaches the background level (OD 280 < 0.05).

Note:

Adding a higher concentration of salts, nonionic detergent, and reducing agents may reduce the nonspecific background. For example, we are adding NaCl (up to 1-1.5 M), 0.1-0.5% nonionic detergents such as Triton X 100 or Tween 20, and a reducing reagent such as DTT or TCEP (usually 3mM) to the washing buffer.

9.

Add 500μL of ultrapure water to the tube and gently mix. Collect the beads on a magnetic stand and discard the supernatant.

10.

Add 10-100μL of Elution Buffer and pipette up and down 10-20 times. Collect the supernatant into a fresh tube. Add 1/10th of
Neutralization Buffer.

Troubleshooting

Problem

The yield of the purified protein is too low or undetectable in eluted protein solution by SDS-PAGE.

Probable Cause

The protein degraded or unstable

Suggestion

Add protease inhibitors.

Problem

The yield of the purified protein is too low or undetectable in eluted protein solution by SDS-PAGE.

Probable Cause

Not enough magnetic beads were used.

Suggestion

Increase the amount of magnetic bead used for capture.

Problem

The yield of the purified protein is too low or undetectable in eluted protein solution by SDS-PAGE.

Probable Cause

The protein does not bind to the Magnetic Beads.

Suggestion

Check the pH of all the buffers and solutions.

Problem

The yield of the purified protein is too low or undetectable in eluted protein solution by SDS-PAGE.

Probable Cause

The sample had an insufficient amount of target protein

Suggestion

Increase the amount of antigen sample.

Problem

The yield of the purified protein is too low or undetectable in eluted protein solution by SDS-PAGE.

Probable Cause

The protein is not efficiently eluted from beads.

Suggestion

Increase incubation time with elution buffer.

Problem

Observe multiple bands in the eluted protein

Probable Cause

Nonspecific protein bound to the magnetic beads

Suggestion

Increase NaCl to the Binding/Wash Buffers.

Problem

Observe multiple bands in the eluted protein

Probable Cause

Degradation of the antigen

Suggestion

Add appropriate protease inhibitor.

Problem

Observe multiple bands in the eluted protein

Probable Cause

The washing condition is not optimized.

Suggestion

  • Increase the concentration of detergent, reducing agent, or salt.
  • Increase washing time and washing volume.

Problem

Probable Causes

Suggestions

The yield of the purified protein is too low or undetectable in eluted protein solution by SDS-PAGE.

The protein degraded or unstable

Add protease inhibitors.

Not enough magnetic beads were used.

Increase the amount of magnetic bead used for capture.

The protein does not bind to the Magnetic Beads.

Check the pH of all the buffers and solutions.

The sample had an insufficient amount of target protein

Increase the amount of antigen sample.

The protein is not efficiently eluted from beads.

Increase incubation time with elution buffer.

Observe multiple bands in the eluted protein

Nonspecific protein bound to the magnetic beads

Increase NaCl to the Binding/Wash Buffers.

Degradation of the antigen

Add appropriate protease inhibitor.

The washing condition is not optimized.

  • Increase the concentration of detergent, reducing agent, or salt
  • Increase washing time and washing volume

Welcome to BitClone

Magnetic Beads Make Things Simple