Products

One-Step Deproteinizing Sample Preparation

Products

BcMag™ One-Step Deproteinizing Kit
Cat. No.  BB101

Unit Size  1 ml
Order
BcMag™ One-Step Deproteinizing Kit
Cat. No.  BB102

Unit Size  5 ml
Order
Previous slide
Next slide

Cat. No.

BB101

BB102

Product Name

BcMag™ One-Step Deproteinizing Kit

BcMag™ One-Step Deproteinizing Kit

Unit Size

1 ml

5 ml

Order

Specification

Composition

Magnetic beads are modified with our proprietary chemistry.

Stability

Short Term (<1 hour): pH 4-11; Long-Term: pH 4-10

Temperature: 4°C -140°C; Most organic solvents

Magnetization

~40-45 EMU/g

Type of Magnetization

Superparamagnetic

Formulation

100 mg / ml in dH2O

Binding Capacity

50 µg proteins/mg of Beads

Storage

Ship at room temperature, Store at 4°C upon receipt.

Description

Introduction

The presence of protein and lipids in biological fluid samples frequently interferes with small molecule analysis, decreasing accuracy and sensitivity. Numerous bioassays need the removal of proteins (deproteinization) and lipids (delipidation) from samples before analysis, such as LC/MS/MS analysis.

Precipitation using trichloroacetic acid, perchloric acid, phosphotungstic acid, acetonitrile, methanol, and other organic solvents has been extensively used for deproteinization over the last half-century. However, these procedures are not only tedious, time-consuming, and challenging to adapt to automation but also inefficiently remove lipids and nucleic acids. BcMag™ One-Step Deproteinizing Kit provides a novel solution for the deproteinization, delipidation, and nucleic acid from biological fluid samples such as cell lysis, plasma, serum, tissue homogenate, and urine for analysis of a variety of small molecules. The superparamagnetic magnetic beads efficiently utilize the proprietary matrix to bind proteins and lipids in the sample. The one-minute protein removal protocol is straightforward: one step, one tube, no precipitation, no filtration, and no centrifugation. The resin enables 96 samples to be processed simultaneously in less than 10 minutes.

Workflow

Features and Advantages

Fast and straightforward protocol: one step, one tube, process 96 samples in less than 10 minutes

Easy-to-use: Eliminates columns, filters, laborious repeat pipetting or centrifugation, and easily adjusts for sample size and automation

No organic solvents/acids precipitation

Efficient deproteinization

PROTOCOL

A. Materials Required by the User

Item

Magnetic Rack for centrifuge tube


** Based on sample volume, the user can choose one of the following magnetic Racks

Source

•  BcMag™ Rack-2 for holding two individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-01)

•  BcMag™ Rack-6 for holding six individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-02)

•  BcMag™ Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Bioclone, Cat. No. MS-03)

•  BcMag™ Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-04)

Item

BcMag™ 96-well Plate Magnetic Rack.

Source

•  BcMa™ 96-well Plate Magnetic Rack (side-pull) compatible with 96-well PCR plate and 96-well microplate or other compatible Racks (Bioclone, Cat. No. MS-05)

Item

Adjustable Single and Multichannel Pipettes

Item

Centrifuge with Swinging Bucket

Addition items are required if using 96-well PCR plates / tubes

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 2000 rpm

Eppendorf™ MixMate™

Eppendorf, Cat. No. 5353000529

Tube Holder PCR 96

Eppendorf, Cat. No. 022674005

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Eppendorf, Cat. No. 022674048

Smart Mixer, Multi Shaker

BenchTop Lab Systems, Cat. No. 5353000529

1.5/2.0 mL centrifuge tube

96-well PCR Plates or 8-Strip PCR Tubes

PCR plates/tubes

** IMPORTANT! If using other tubes or PCR plates, make sure that the well diameter at the bottom of the conical section of PCR Tubes or PCR plates must be ≥2.5mm.

Items

Magnetic Rack for centrifuge tube

** Based on sample volume, the user can choose one of the following magnetic Racks

Source

BcMag™ Rack-2 for holding two individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-01)

BcMag™ Rack-6 for holding six individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-02)

BcMag™ Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Bioclone, Cat. No. MS-03)

BcMag™ Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-04)

BcMag™ 96-well Plate Magnetic Rack

BcMa™ 96-well Plate Magnetic Rack (side-pull) compatible with 96-well PCR plate and 96-well microplate or other compatible Racks (Bioclone, Cat. No. MS-05)

Adjustable Single and Multichannel Pipettes

Centrifuge with Swinging Bucket

Addition items are required if using 96-well PCR plates/tubes

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and Speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 2000 rpm

Eppendorf™ MixMate™

Tube Holder PCR 96

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Smart Mixer, Multi Shaker

Eppendorf, Cat. No. 5353000529

Eppendorf, Cat. No. 022674005

Eppendorf, Cat. No. 022674048

BenchTop Lab Systems, Cat. No. 5353000529

Eppendorf™ MixMate™

Tube Holder PCR 96

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Smart Mixer, Multi Shaker
 

Eppendorf, Cat. No. 5353000529

Eppendorf, Cat. No. 022674005

Eppendorf, Cat. No. 022674048
 

BenchTop Lab Systems, Cat. No. 5353000529

1.5/2.0 mL centrifuge tube

96-well PCR Plates or 8-Strip PCR Tubes

PCR Plates/Tubes

! IMPORTANT ! If using other tubes or PCR plates, ensure that the well diameter at the bottom of the conical section of PCR Tubes or PCR plates must be ≥2.5mm.

B. Procedure

Notes:

Do not use buffers containing organic solvents.

For the best results, ensure that the sample pH should be ~4.5.

1.

Dilute and adjust the protein concentration in sample ~1mg/ml and pH to 4.5 by sodium acetate or other buffers.

2.

Shake the bottle to resuspend the Magnetic Beads until it is homogeneous completely.

! IMPORTANT ! 

  • Resuspend the magnetic Beads every 2 minutes. It is essential to mix the Beads before dispensing. Do not allow the Beads to sit for more than 2 minutes before dispensing.

3.

Add an appropriate amount of the magnetic Beads to the sample (Beads amount should be calculated based on the sample protein concentration and the Beads binding capacity, ~50µg protein/mg Beads.)

4.

Mix the sample with beads for 1-2 minutes by slowly pipetting up and down 20-25 times or Vortex the sample for 5 minutes at 2000 rpm for the PCR tube or 800 rpm for Elisa plates.

! IMPORTANT ! 

  • Users need to optimize the beads and free detergents ratio based on the binding capacity listed in table 1 and the Speed and Time if using a vortex mixer.

5.

Place the sample plate or tube on the magnetic rack for 30 seconds or until the solution is clear.

(Option: centrifuge at 3500 rpm for 45 seconds)

6.

Transfer the supernatant to a clean plate/tube while the sample plate remains on the magnetic separation plate. The sample is ready for downstream applications.

C. Troubleshooting

Problem

Deproteinization efficiency is low.

Probable Cause

  • Too many proteins in your sample
  • Check the sample pH and make sure the pH is ~ 4.5

Suggestion

  • Repeat the same procedure
  • Adjust sample pH to 4.5

Problem

Probable Cause

Suggestion

Deproteinization efficiency is low.

  • Too many proteins in your sample
  • Check the sample pH and make sure the pH is ~ 4.5.
  • Repeat the same procedure
  • Adjust sample pH to 4.5

General Reference

1.

Hušek P, Svagera Z, Hanzlíková D, Simek P. Survey of several methods deproteinizing human plasma before and within the chloroformate-mediated treatment of amino/carboxylic acids quantitated by gas chromatography. J Pharm Biomed Anal. 2012 Aug-Sep;67-68:159-62. doi: 10.1016/j.jpba.2012.04.027. Epub 2012 May 7. PMID: 22633606.

2.

Sakuma R, Nishina T, Kitamura M. Deproteinizing methods evaluated for determination of uric acid in serum by reversed-phase liquid chromatography with ultraviolet detection. Clin Chem. 1987 Aug;33(8):1427-30. PMID: 3608161.

3.

Álvarez-Guerra ED, Parkes HG, Bell JD. Comparative study of two deproteinization methods for the evaluation of whole blood and plasma by magnetic resonance spectroscopy. Bioquimia. 2006;31(2):59-68.

4.

Daykin CA, Foxall PJ, Connor SC, Lindon JC, Nicholson JK. The comparison of plasma deproteinization methods for the detection of low-molecular-weight metabolites by (1)H nuclear magnetic resonance spectroscopy. Anal Biochem. 2002 May 15;304(2):220-30. doi: 10.1006/abio.2002.5637. PMID: 12009699.

5.

Chen, Y., Xie, M., Li, W. et al. An effective method for deproteinization of bioactive polysaccharides extracted from lingzhi (Ganoderma atrum). Food Sci Biotechnol 21, 191–198 (2012).

6.

Dziurkowska, E.; Wesolowski, M. Deproteinization as a Rapid Method of Saliva Purification for the Determination of Carbamazepine and Carbamazepine-10,11 Epoxide. J. Clin. Med. 2020, 9, 915. https://doi.org/10.3390/jcm9040915

Welcome to BitClone

Magnetic Beads Make Things Simple